Stay updated with the most recent editions of ODT Magazine, featuring comprehensive coverage of the latest innovations and developments.
Access the full digital version of ODT Magazine, complete with interactive features and enhanced content for a seamless reading experience.
Join the ODT community! Subscribe to receive the latest industry news and insights delivered directly to your mailbox.
Discover how 3D printing and additive manufacturing are revolutionizing orthopedic device design and production processes.
Learn about contract manufacturing solutions in the orthopedic sector, emphasizing quality, compliance, and operational excellence.
Stay informed on the latest research and development trends in orthopedic device design, driving innovation and patient care improvements.
Explore the latest advancements in surgical instruments and technologies that enhance precision and outcomes in orthopedic procedures.
Discover cutting-edge machining and laser processing techniques that improve the quality and performance of orthopedic devices.
Learn about the innovative materials shaping orthopedic devices, focusing on performance, biocompatibility, and regulatory compliance.
Stay updated on advanced molding techniques for producing high-quality orthopedic components that meet industry standards.
Explore best practices for packaging and sterilization methods that ensure the safety and efficacy of orthopedic devices.
Discover the role of software solutions in enhancing orthopedic device design, functionality, patient management, and regulatory compliance.
Learn about essential testing methods and standards that ensure the safety, reliability, and effectiveness of orthopedic devices.
Stay ahead with real-time updates on significant news impacting the orthopedic device sector.
Access unique content and insights not available in the print edition of ODT Magazine, offering deeper dives into important topics.
Explore feature articles that provide in-depth analysis on specific topics within orthopedic design and technology.
Gain insights from industry experts through regular columns addressing critical challenges and innovations in orthopedics.
Read the editorial insights on current trends and highlights from the latest issue of ODT Magazine.
Discover leading companies in orthopedic design and technology, showcasing their innovations and contributions to the field.
Explore detailed profiles of companies in the orthopedic device manufacturing sector, highlighting their capabilities and offerings.
Learn about the expertise and resources of leading companies in the orthopedic device manufacturing sector.
Watch informative videos featuring industry leaders discussing trends, technologies, and innovations in orthopedic design.
Enjoy short, engaging videos that provide quick insights and updates on key topics within orthopedics.
Tune in to discussions with industry experts sharing their insights on trends, challenges, and innovations in orthopedic technology.
Participate in informative webinars led by industry experts covering various relevant topics in orthopedic design and manufacturing.
Stay informed on the latest press releases and announcements from leading companies in the orthopedic device manufacturing sector.
Access comprehensive eBooks that delve into various topics in orthopedic device manufacturing and innovation.
Highlighting the pioneers and innovators driving advancements in orthopedic technology and patient care.
Explore sponsored articles and insights from leading companies in the orthopedic industry.
Read in-depth whitepapers that examine key issues, trends, and research findings in orthopedic design and technology.
Discover major industry events, trade shows, and conferences focused on orthopedic technology and innovations.
Get real-time updates and insights from major industry shows and exhibitions happening around the world.
Participate in the ODT Forum, addressing orthopedic design and manufacturing technology trends, innovations, and industry challenges.
Attend the MPO Summit for insights and strategies from industry leaders shaping the future of medical device technology.
Join discussions and networking opportunities at the MPO Medtech Forum, focusing on the latest trends and challenges in the industry.
Explore advertising opportunities with ODT to connect with a targeted audience of orthopedic professionals.
Review our editorial guidelines for submissions and contributions to ODT.
Read about our commitment to protecting your privacy and personal information.
Familiarize yourself with the terms and conditions governing the use of odtmag.com.
What are you searching for?
New technique improves lubrication of implants for artificial hips; might reduce or eliminate the need for revision surgery.
May 14, 2018
By: University of Arkansas, Fayetteville
Mechanical engineering researchers have developed a method that could extend the life of an artificial hip by adding an array of microscopic indentations that increase the thickness of a lubricating film on its surface. “Lubrication plays a key role in the wear process of the implanted joint interface,” said Min Zou, professor of mechanical engineering. “But this mechanism is challenging to understand because of the complex nature of the viscous fluid used for lubrication. Our study reveals promising results for understanding this mechanism better and significantly improving implants.” Each year in the United States, orthopedic surgeons perform more than 300,000 hip-replacements, including roughly 36,000 revision surgeries when a replacement wears out. Though there are several environmental factors that affect the health and longevity of artificial hips, these implants last an average of 15 to 20 years. However, about half of all hip-replacement surgeries are performed on patients between the ages of 45 and 64, people who could live another 25 or 30 years. Hip-replacement procedures involve the surgical removal and artificial replacement of the femoral head—the top of the femur, or thigh bone—and part of the pelvis called the acetabulum, a concave surface into which the femoral head fits. Many people refer to this joint as a ball and socket—the femoral head acting as the ball and the acetabulum as the socket. A primary reason for artificial joint failure—and thus the need for revision surgery—is a loosening of the bond between the implant and bone, which in many cases is caused by the body’s autoimmune response to particles and wear on the surface of the implant, as well as the toxicity of metallic ions released into the body because of this wear. To address this problem, researchers focus on a lubricating film that forms between the interacting surfaces of the femoral head and the acetabulum. This film is created by a naturally occurring lubricant called synovial fluid, which is produced and released by cartilage. Although cartilage is also removed during hip-replacement surgery, the body produces enough synovial fluid to form a thin layer between the implants. The formation of this film after surgery and especially its thickness determine the long-term success of the implant. The U of A experiment was designed by Dipankar Choudhury, post-doctoral fellow in the Center for Advanced Surface Engineering, and performed at the direction of Zou, who is director of the center. Their results were published in the Journal of the Mechanical Behavior of Biomedical Materials. Rather than manipulating synovial fluid, which most hip prosthesis research focuses on, Zou and Choudhury simulated the textured surface of cartilage, its so-called “converging gaps,” or natural dimples, that promote the secretion of synovial fluid and enhance the thickness of the lubricating film. Zou and Choudhury designed square-, triangular- and elliptical-shaped indentations on the surface of artificial femoral heads. (Magnified images resemble the surface of a golf ball.) These prostheses were made of chromium, cobalt and molybdenum, the standard metallic alloy for hip-replacement implants. The indentations, fabricated with a picosecond laser by a collaborator in Japan, were 20 to 50 micrometers wide and 0.2 to 1 micrometer deep. Then, collaborating with a research group in the Czech Republic, Zou and Choudhury joined the prosthetic parts and performed wear and friction tests with a pendulum that simulated the swinging motion of a human leg. When the pendulum returned to equilibrium position—after the lubricant film had fully developed—test results revealed significantly enhanced thickness of film. Compared to the non-dimpled prostheses, all three shapes improved lubricant film thickness. The prostheses with square- and triangular-shaped indentations demonstrated an average lubricant film thickness 3.5 times greater than the non-dimpled prosthesis. The prosthesis with square-shaped indentations formed its lubricant film less than a second after the pendulum started moving, much faster than all other prostheses, including those with indentations made of other shapes. This clearly demonstrated that shape had a significant effect, Choudhury said. “Also, hardly any scratches appeared on the post-experimental prosthesis with square-shaped dimple arrays, and only a few scratches were found on the prosthesis with triangular-shaped dimple arrays,” said Zou. “We think that prostheses with square-shaped dimples could be a potential solution for durable, longer-lasting artificial hip joints.” Zou recently developed processes for fabricating smaller micro-dimples of various complex shapes, which are expected to further decrease friction and wear of the prosthetic joints. Zou holds the Twenty-First Century Professorship in mechanical engineering. In 2015, she received a $20 million National Science Foundation/EPSCoR (Experimental Program to Stimulate Competitive Research) grant and an additional $4 million matching funds from the state, which enabled the university to establish the statewide Center for Advanced Surface Engineering. The center promotes statewide scientific progress by establishing partnerships with government, higher education and industry. Find more information on the study here.
Enter your account email.
A verification code was sent to your email, Enter the 6-digit code sent to your mail.
Didn't get the code? Check your spam folder or resend code
Set a new password for signing in and accessing your data.
Your Password has been Updated !